Linearity range potassium : 0~30mg/|, correlation coefficient greater than 0.999
Measurement range K: 0~10mmo|/L Na:0~200mmo|/L
Repetitiveness (GV%):K:1.5%(5mmo|/L or 50mmo|/L) Na :1.0%(140 mmol /L)
Linearity error K:2%;Na:2%: within 8s
Solution consumption 4ml /min extinguishing tester.automatic disconnection gas function
Bring RS232 interface , can be connected with computer
Dimension:58*38*33cm
8. Weight:35kg
JKI JK-FP6400 Flame Photometer

Wavelength range ( 335-1000) nm, wildly used.
Built-in Single-Chip coumputer, high automaticity instrument, automaticly adjust 0%(τ), automaticly adjust 100%(τ) and zero tolerance τ-A switching, more handy than the original 721 model.
LED digital display
4 modes of measurement: transmittance(τ), absorbance(A), direct reading of concentration(C) and confficient determination(F), completely comply with testing requests.
Advanced optical system,superior C-T model monochromator’s beamsplitter highly optimize these indexs :resolution, photometric accuracy, stray light.
Appropriative precision presetting lamp or a lamp holder. Our users don’t need to readjust light path when changing the lamp. It will be more handy for our users.
Sample room is made of special engineering plastic bearing solvent and strong sour alkali. In the bottom side installed a removable a container for liquid to meet needs of some of our users.
Staphylococcus tetragenus , 10-50 mm cuvette can be used
Insulated plastic shell, small volume, light in weight, good figure.
Main specifications:
Optical system: C-T monochromator(diffraction grating)
Wavelength range: 335nm-1000nm
Wavelength accuracy: ±3.0 nm
Wavelength repeatability: ≤1.5 nm
Spectral bandwidth: 6 nm
Spectral range: τ:0.0-199.9%(τ)
A:-0.300-2.999(A)
C:0-9999(C)
F:1-9999(F)
Transmittance accuracy: ±1.0%τ(0-100%τ)
Transmittance repeatability: ≤0.3%τ(0-100%τ)
Stray light: ≤1.0%(τ)
Stability: dark current: ≤0.3%τ/3min light current: ≤1.0%τ/3min
Operation mode: manual operation
Dimension: 500mm×400mm×300mm(W×D×H)
Supply voltage: AC220V±22V;Frequency:50Hz±1Hz(supply voltage for foreign products can be customized according to customer’s needs)
Weight: 10kg
JKI JK-VS-721N Visiable Spectrophotometer
JKI JK-UVS-759MC UV-VIS Spectrophotometer
Wavelength Range(nm):190~1100
Wavelength MPE(nm):±0.5
Wavelength Repeatability(nm):≤0.2
Luminosity Range :0~200% -0.301~3.000A 0.000~99999C
Transmissivity MPE(%): ±0.3
Transmissivity Repeatability(%): ≤0.15
Spectral Bandwidth(nm): 1.5±0.3
Stray light(%):0.05(220nm、360nm)
Noise(%):100 noise≤0.15 0 noise≤0.1
Drift(A): ≤0.0007
Baseline Flatness(A): ±0.002
Diamension (mm) : 500mm*600mm*300mm(W*D*H)
Weight:17kg
Instrument Level : Ⅱ

Wavelength range: 200nm-1000nm
Wavelength accuracy: ≤±2nm
Wavelength repeatability: ≤1nm
Transmittance accuracy:0.5%(t)(NBS930D)
Transmittance repeatability: ≤0.2%(τ)
Spectrol bandwidth: 4nm
Stay light: ≤0.5%(τ)(at 220nm, Nal)
Stability: Dark current drift: 0.2%(t)/3min
Light current drift: 0.5%(t)/3min
Dimension: 500mm*600mm*300mm(W*D*H)
Power supply voltage: AC220V±22V;frequency 50Hz±1Hz (supply voltage for foreign trade can be customized according to customer’s needs)
Weight: 17kg
JKI JK-UVS-752N Ultraviolet Visible Spectrophotometer


JKI JK-AAS-4530F/JK-AAS-4530TF Atomic Absorption Spectrophotometer
JKI JK-FP640 Flame Photometer
Wavelength range:190-900nm
Spectrol bandwidth:0.1,0.2,0.4,0.7,1.0,2.0nm automatic switch
Wavelength accuracy:±0.2nm
Wavelength repeatability:0.1nm
Baseline drift:0.002A/30min
Background adjustment:School deuterium lamp background, self-absorption background correction
Flame analysis
Characteristic concentration(Cu): ≤0.025ug/ml/1%
Precision(Cu): ≤0.5%
Detection limit(Cu): ≤0.008ug/ml)
Furnace analysis
Characteristic quantities: Cd ≤1pg,Cu≤10pg
Detection limit: Cd:≤2pg
Precision: Cd≤3%,Cu≤3%
Dimension: 58*32*27mm
Weight: 35kg.


Linearity range potassium : 0~30mg/|, correlation coefficient greater than 0.999
Measurement range K: 0~10mmo|/L Na:0~200mmo|/L
Repetitiveness (GV%):K:1.5%(5mmo|/L or 50mmo|/L) Na :1.0%(140 mmol /L)
Linearity error K:2%;Na:2%: within 8s
Solution consumption 4ml /min extinguishing tester.automatic disconnection gas function
Bring RS232 interface , can be connected with computer
Dimension:58*38*33cm
Weight:35kg
JKI 722N Visiable Spectrophotometer

Wavelength range: 335nm-1000nm
Wavelength accuracy: ≤±2nm
Wave repeatability: ≤1nm
Transmittance accuracy: ≤±0.5%(τ)
Transmittance repeatability: ≤0.2%(τ)
Spectral bandwidth: 4nm
Stray light: ≤0.1%(t)(at 360nm NaNO2)
Stability: dark current drift: 0.2% (T) / 3 min light current drift: 0.5% (T) / 3 min
LED display (with backlight)
Supply voltage: AC85V-242V;
Overall dimensions:700mm*650mm*400mm
Weight:10.5kg