top of page

Linearity range  potassium : 0~30mg/|, correlation coefficient greater than 0.999

Measurement range   K: 0~10mmo|/L  Na:0~200mmo|/L

Repetitiveness       (GV%):K:1.5%(5mmo|/L or 50mmo|/L)   Na :1.0%(140 mmol /L)

Linearity error        K:2%;Na:2%: within 8s

Solution consumption  4ml /min extinguishing tester.automatic disconnection gas function

Bring  RS232  interface , can be connected with computer

Dimension:58*38*33cm

8. Weight:35kg

JKI    JK-FP6400 Flame Photometer

Wavelength range ( 335-1000) nm, wildly used.

Built-in Single-Chip coumputer, high automaticity instrument, automaticly adjust 0%(τ), automaticly adjust 100%(τ) and zero tolerance τ-A switching, more handy than the original 721 model.

LED digital display

4 modes of measurement: transmittance(τ), absorbance(A), direct reading of concentration(C) and confficient determination(F), completely comply with testing requests.

Advanced optical system,superior C-T model monochromator’s  beamsplitter highly optimize these indexs :resolution, photometric accuracy, stray light.

Appropriative precision presetting lamp or a lamp holder. Our users don’t need to readjust light path when changing the lamp. It will be more handy for our users.

Sample room is made of special engineering plastic bearing solvent and strong sour alkali. In the bottom side installed a removable a container for liquid to meet needs of some of our users.

Staphylococcus tetragenus , 10-50 mm cuvette can be used

Insulated plastic shell, small volume, light in weight, good figure.

 

Main specifications:

Optical system: C-T monochromator(diffraction grating)

Wavelength range: 335nm-1000nm

Wavelength accuracy: ±3.0 nm

Wavelength repeatability: ≤1.5 nm

Spectral bandwidth: 6 nm

Spectral range: τ:0.0-199.9%(τ)
A:-0.300-2.999(A)
C:0-9999(C)
F:1-9999(F)

Transmittance accuracy: ±1.0%τ(0-100%τ)

Transmittance repeatability: ≤0.3%τ(0-100%τ)

Stray light: ≤1.0%(τ)

Stability: dark current: ≤0.3%τ/3min  light current: ≤1.0%τ/3min

Operation mode: manual operation 

Dimension: 500mm×400mm×300mm(W×D×H)

Supply voltage: AC220V±22V;Frequency:50Hz±1Hz(supply voltage for foreign products can be customized according to customer’s needs)

Weight: 10kg

JKI   JK-VS-721N Visiable Spectrophotometer

JKI   JK-UVS-759MC UV-VIS Spectrophotometer

Wavelength Range(nm):190~1100 

Wavelength MPE(nm):±0.5 

Wavelength Repeatability(nm):≤0.2 

Luminosity Range :0~200%    -0.301~3.000A    0.000~99999C 

Transmissivity MPE(%): ±0.3

Transmissivity Repeatability(%): ≤0.15 

Spectral Bandwidth(nm): 1.5±0.3 

Stray light(%):0.05(220nm、360nm) 

Noise(%):100 noise≤0.15   0 noise≤0.1 

Drift(A): ≤0.0007 

Baseline Flatness(A): ±0.002 

Diamension (mm) : 500mm*600mm*300mm(W*D*H)

Weight:17kg

Instrument Level : Ⅱ

Wavelength range: 200nm-1000nm

Wavelength accuracy: ≤±2nm

Wavelength repeatability: ≤1nm

Transmittance accuracy:0.5%(t)(NBS930D)

Transmittance repeatability: ≤0.2%(τ)

Spectrol bandwidth: 4nm

Stay light: ≤0.5%(τ)(at 220nm, Nal) 

Stability: Dark current drift: 0.2%(t)/3min

Light current drift: 0.5%(t)/3min

Dimension: 500mm*600mm*300mm(W*D*H)

Power supply voltage: AC220V±22V;frequency 50Hz±1Hz (supply voltage for foreign trade can be customized according to customer’s needs)

Weight: 17kg

JKI   JK-UVS-752N Ultraviolet Visible Spectrophotometer

JKI   JK-AAS-4530F/JK-AAS-4530TF Atomic Absorption Spectrophotometer

JKI   JK-FP640 Flame Photometer

Wavelength range:190-900nm 

Spectrol bandwidth:0.1,0.2,0.4,0.7,1.0,2.0nm automatic switch 

Wavelength accuracy:±0.2nm 

Wavelength repeatability:0.1nm 

Baseline drift:0.002A/30min 

Background adjustment:School deuterium lamp background, self-absorption background correction 

Flame analysis 

Characteristic concentration(Cu): ≤0.025ug/ml/1% 

Precision(Cu): ≤0.5% 

Detection limit(Cu): ≤0.008ug/ml) 

Furnace analysis 

Characteristic quantities: Cd ≤1pg,Cu≤10pg 

Detection limit: Cd:≤2pg 

Precision: Cd≤3%,Cu≤3% 

Dimension: 58*32*27mm 

Weight: 35kg.  

Linearity range  potassium : 0~30mg/|, correlation coefficient greater than 0.999

Measurement range   K: 0~10mmo|/L  Na:0~200mmo|/L

Repetitiveness       (GV%):K:1.5%(5mmo|/L or 50mmo|/L)   Na :1.0%(140 mmol /L)

Linearity error        K:2%;Na:2%: within 8s

Solution consumption  4ml /min extinguishing tester.automatic disconnection gas function

Bring  RS232  interface , can be connected with computer

Dimension:58*38*33cm

Weight:35kg

JKI   722N Visiable Spectrophotometer

Wavelength range: 335nm-1000nm

Wavelength accuracy: ≤±2nm

Wave repeatability: ≤1nm

Transmittance accuracy: ≤±0.5%(τ)

Transmittance repeatability: ≤0.2%(τ)

Spectral bandwidth: 4nm

Stray light: ≤0.1%(t)(at 360nm NaNO2)

Stability: dark current drift: 0.2% (T) / 3 min          light current drift: 0.5% (T) / 3 min

LED display (with backlight)

Supply voltage: AC85V-242V; 

Overall dimensions:700mm*650mm*400mm

Weight:10.5kg

bottom of page